Briefintroduction ACD-102 Pressure transmitter is new product developed on our history experience. There is build-in battery makes the transmitter measure without external power. This transmitter cannot only output signal 4-20mA but also c

Customized

  • Product description

Brief introduction
ACD-102 Pressure transmitter is new product developed on our history experience. There is build-in battery makes the transmitter measure without external power. This transmitter cannot only output signal 4-20mA, but also can add RS485 communication. It adopts the most advanced micro power and perfect software technology and five figures backlit displayed on LCD screen.








Product features
1. 11 units display: Pa  kPa  MPa  psi  bar  mbar  kgf/cm2  inH2O  mmH2O  inHg  mmHg
2. support RS485 and RS232 communication or 4-20mA or 1-5V output, free to choose
3. radial, axial, plate, spilt and investment installation type
4. five figures display on LCD screen and backlit function easy to read at night
5. never drop communication equipment, the trunk support 255sets of RS485 counter equipment
6. signal isolation technique, anti-electromagnetic interference and RFI technique
7. zero stable technology, increase the stability of the instrument

Product application
1. replace the imported transmitter outdoors or under bad environment
2. acquisition or communication whole day in the pit
3. oil well and gas well pressure monitoring and remote transmission
4. suit for large areas pressure parameters group acquisition
5. can work well in corrosive, impact and versatility environment
6. equipped with AncnView-T digital instrument test monitoring software

Product parameter
1. Display unit: Pa  kPa  MPa  psi  bar  mbar  kgf/cm2  inH2O  mmH2O  inHg  mmHg
2. Measuring Range: Gage Pressure: -0.1MPa~260MPa
                  Differential Pressure: 0~3.5MPa
                     Aboslute Pressure: 0~60MPa
3. Accuracy grade: 0.05  0.1  0.2  0.5
4. Communication: RS485(compatible with modbusRTU and ANCN free protocol )
5. Output signal: 4-20mA two-wire system or 1-5VDC three-wire system.
6. Span shift: suggested less than 3:1
7. Power supply mode:  Inner: 3.6V industry lithium battery
                    External: ACD-102C:(10~30)VDC;
ACD-102D:5VDC
8. Picking rate: Inner: 1-20s per time; External: 0.25s per time
9. Stability Performance:  <0.2% FS per year
10. Operating temperature: -30℃~70℃
11. Relative humidity: <90% 
12. Barometric pressure: 86-106KPa
13. Others: Calibration reference operating temperature 20℃±2℃
0.05 accuracy requires operating temperature 0-50℃
14. Medium Temperature: General temperature range (-40~120)℃
                    Wide temperature range (-60~150)℃
15. Display mode: five figures dynamic display and percentage bar chart
16. Protection Degree: IP65
17. Exdl: ExdIIBT6 Gb  
18. Overload Pressure: 1.5-3 times of measuring range, depending on the measuring range
19. Software configuration: AncnView-T digital instrument test software with RS485 communication displaying instrument data, automatic recording, automatic drawing pressure curve and deriving to Excel, reading, printing and storage.
20. Process Connection: Metric M20×1.5、M14×1.5、M14×1
             US/UK Standard: G1/2、G3/4、G1/8、G3/8, NPT 1/2、NPT 1/4、NPT 1/8
 
Install mode
Product model selection: